3165033 Inline 6 Data Link Adapter Diagnostic Tool For Cummins Komatsu TMC's Kit

£191.99 Buy It Now, Click to see shipping cost, 30-Day Returns, eBay Money Back Guarantee
Seller: sinocmp-parts ✉️ (779) 98.5%, Location: GB, Ships to: GB, Item: 313316039668 3165033 Inline 6 Data Link Adapter Diagnostic Tool For Cummins Komatsu TMC's Kit.

3165033 Inline 6 Data Link Adapter Diagnostic Tool For Cummins Komatsu TMC's Kit

3165033 Inline 6 Data Link Adapter Diagnostic Tool For Cummins Komatsu TMC's Kit

SINOCMP 3165033 Full 8 cable INLINE 6 Data Link Adapter Insite Heavy Duty Diagnostic Tool Scanner  INLINE 6 Data Link Adapter For Cummins

        Get INLINE 6 for 5 Reasons:
  • The INLINE 6 can communicate with your PC through a 9-pin serial connector. The INLINE 6 also can communicate with your PC over a Universal Serial Bus (USB) through a 4-pin standard connector. The INLINE 6 adapter connects to vehicle power, the SAE J1708/J1587 data link, and two CAN/J1939 data links via a 25-pin serial connector.
  • With full compliance to the Technology and Maintenance Council's RP1210 standard, the INLINE 6 will work with the latest  INSITE, PowerSpec and Calterm III software applications.
  • It will also work with any other software applications that are fully compliant with the RP1210 standard (note that while some non- applications fully support RP1210, others do not, so you should test each application in question with the INLINE 6 adapter to make that determination).
  • The eye-catching INLINE 6 breaks new ground by utilizing the latest electronic technology to deliver high performance and high quality at an attractive price.
  • Each INLINE kit contains a data link adapter, basic cables, and the INLINE PC software driver. Load the software driver, connect all the hardware, and you are ready to start a new era in data link adapters.

    INLINE 6 Features:
  • Supports SAE J1708/J1587 and J1939/CAN data links
  • Both CAN ports auto detect between 250 & 500 kbps
  • Supports USB full speed port at up to 2M baud rate
  • Custom USB cable includes thumbscrews for secure mounting to INLINE 6
  • Supports RS-232 PC serial port at up to 115.2k baud rate
  • Is fully compliant with TMC's RP1210 standard
  • Small enough to fit in pocket
  • Attractive black powder coated aluminum housing provides ruggedness
  • Derives 8 V to 50 V DC power from vehicle
  • Controlled by advanced 140 MHz 32-bit Freescale processor for maximum speed and performance
  • Includes 6 LEDs to indicate status of power, USB, RS-232, J1708/J1587, and two CAN communication ports
  • Both CAN ports support SAE J1939, SAE J2534, and ISO 15765 protocols
  • INLINE 6 is certified to meet European CE requirements
  • Rated for -40° to +85° C operating temperature
  • INLINE 6 meets rigorous  in-cab environmental test requirements
  • Inline 6 data link adapter Support Language:
          Package Including:
  • 1 x INLINE 6 data link adapter (P/N 2892093)
  • 1 x USB 14-foot  cable (P/N 2892176)
  • 1 x DB25F/9-pin data link cable (P/N 4919780)
  • 1 x DB25F/3-pin/3-pin/2-pin cable (P/N 4919797)
  • 1 x J1939 Gender Changer adapter (P/N 3163597)
  • 1 x J1939 Backbone adapter (P/N 3163096)
  • 1 x ObdII cable  (P/N 4919781)
  • 1 x INLINE 6 software CD (P/N 2892095)  Include Insite 7.6.2 + keygen
INLINE 6 Quick Start Guide Introduction   The INLINE 6 is a highly reliable datalink adapter that can be used on a wide range of applications to communicate with vehicle systems via SAE J1708/J1587 and SAE J1939 protocols. Please note that the INLINE 6 is designed to be used with RP1210 compliant software.  Minimum System Requirements  Microprocessor – Intel Pentium 500 MHz  Memory – 2 GB CD Drive  Operating System – Windows 7, Vista, & XP SP3      To Install the INLINE 6 Software Driver • Insert the INLINE 6 driver CD into your computer’s CD-ROM drive.  • Run INLINE6_Driver_Setup.exe  • If a Windows Explorer folder opens, select INLINE6_Driver_Setup.exe  Note that on some systems the autorun settings may be set to have the installation to just begin executing upon CD insertion.    IF YOU SEE: WINDOWS XP - A message appear stating “The software you are installing has not passed Windows Logo…” Click “Continue Anyway”. Click “Finish” when  installation is complete.    

 

To Install the INLINE 6 USB Hardware: To install the INLINE 6 USB hardware, power up the INLINE 6 by plugging in the USB  cable provided with the kit to the INLINE 6 and the PC. 
  • WINDOWS XP - The Found New Hardware wizard should be displayed.On the first screen, select “Install the software automatically (Recommended)”. Click “Next” to continue. A message may appear “This software has not passed Windows Logo Testing……” Select “Continue Anyway”. Click “Finish” when installation is complete. 
  • WINDOWS VISTA/WINDOWS 7 - No action is required. The system tray  should display a balloon stating “Installing Cummins Inline 6”. 
  • NOTE : If there is a previously installed INLINE 6 driver, you may need to remove the older driver before proceeding. 
  • After you have connected your INLINE 6 to your computer and the computer recognizes it as a valid device – you may need to update the firmware in the adapter. Please see the section below on using the INLINE 6 Reflash Tool
 
  • Using Your INLINE 6
  • To use the INLINE 6, you must select it from within the application you areusing. Each application has a unique method for selecting datalink adapters.Please refer to the application’s documentation for instructions on selectingRP1210 compliant adapters.
  •  
  • To Uninstall the INLINE 6 Software Driver 
  • WINDOWS XP- To remove the Cummins INLINE 6 driver, click the “Start”button on the Windows task bar, and then navigate to “Control Panel”. Navigate to “Add or Remove Programs” Click on the entry “Cummins Inline6”. Click the “Remove” button. This will start the uninstall process. Wait until the uninstall process has completed before proceeding. WINDOWS VISTA/WINDOWS 7 – To remove the Cummins INLINE 6 driver, 
  • click the “Start” button on the Windows task bar, and then navigate to “Control 
  • Panel”. Navigate to “Programs/Features” Click the entry “Cummins Inline6’, 
  • Click “Uninstall” at the top of the Programs/Features window. This will start the 
  • uninstall process. Wait until the uninstall process has completed before proceeding. 
  •  
Shipping Policy
  • Your order will be shipped within 24-48 hours after payment received and order information confirmed.
  • Expedited Shipping(FedEx/DHL/TNT/UPS/4PX): TO UK 3-7 Workdays, to other countries 3-10 Workdays.
  • Economy Shipping(Post/Airmail): TO United Kingdom, Australia 20-35 Workdays, TO Other countries 20-50 Workdays.
  • Full name, correct telephone number and detailed Physical Address(home or office address) address are necessary.
Payment Method
  • Accept PayPal Only. 
  • Import duties, taxes and customs clearance fees are not included in the item price or shipping charges. These charges are the buyer’s responsibility.
Returns Policy
  • We offer return or exchange service in the warranty.
  • Refund will be given after receiving the return parts(Buyer pays return shipping).
  • We maintain high standards of excellence POSITIVE FEEDBACK and strive for 100% customer satisfaction!
About US

 Maintenance service: repairing for monitor, ECU computer and  hydraulic pump; monitor hours resetting, etc.

Store Categories

Store Categories

Product Views

3165033 Inline 6 Data Link Adapter Diagnostic Tool For Cummins Komatsu TMC's Kit

SINOCMP 3165033 Full 8 cable INLINE 6 Data Link Adapter Insite Heavy Duty Diagnostic Tool Scanner  INLINE 6 Data Link Adapter For Cummins

        Get INLINE 6 for 5 Reasons:
  • The INLINE 6 can communicate with your PC through a 9-pin serial connector. The INLINE 6 also can communicate with your PC over a Universal Serial Bus (USB) through a 4-pin standard connector. The INLINE 6 adapter connects to vehicle power, the SAE J1708/J1587 data link, and two CAN/J1939 data links via a 25-pin serial connector.
  • With full compliance to the Technology and Maintenance Council's RP1210 standard, the INLINE 6 will work with the latest  INSITE, PowerSpec and Calterm III software applications.
  • It will also work with any other software applications that are fully compliant with the RP1210 standard (note that while some non- applications fully support RP1210, others do not, so you should test each application in question with the INLINE 6 adapter to make that determination).
  • The eye-catching INLINE 6 breaks new ground by utilizing the latest electronic technology to deliver high performance and high quality at an attractive price.
  • Each INLINE kit contains a data link adapter, basic cables, and the INLINE PC software driver. Load the software driver, connect all the hardware, and you are ready to start a new era in data link adapters.

    INLINE 6 Features:
  • Supports SAE J1708/J1587 and J1939/CAN data links
  • Both CAN ports auto detect between 250 & 500 kbps
  • Supports USB full speed port at up to 2M baud rate
  • Custom USB cable includes thumbscrews for secure mounting to INLINE 6
  • Supports RS-232 PC serial port at up to 115.2k baud rate
  • Is fully compliant with TMC's RP1210 standard
  • Small enough to fit in pocket
  • Attractive black powder coated aluminum housing provides ruggedness
  • Derives 8 V to 50 V DC power from vehicle
  • Controlled by advanced 140 MHz 32-bit Freescale processor for maximum speed and performance
  • Includes 6 LEDs to indicate status of power, USB, RS-232, J1708/J1587, and two CAN communication ports
  • Both CAN ports support SAE J1939, SAE J2534, and ISO 15765 protocols
  • INLINE 6 is certified to meet European CE requirements
  • Rated for -40° to +85° C operating temperature
  • INLINE 6 meets rigorous  in-cab environmental test requirements
  • Inline 6 data link adapter Support Language:
          Package Including:
  • 1 x INLINE 6 data link adapter (P/N 2892093)
  • 1 x USB 14-foot  cable (P/N 2892176)
  • 1 x DB25F/9-pin data link cable (P/N 4919780)
  • 1 x DB25F/3-pin/3-pin/2-pin cable (P/N 4919797)
  • 1 x J1939 Gender Changer adapter (P/N 3163597)
  • 1 x J1939 Backbone adapter (P/N 3163096)
  • 1 x ObdII cable  (P/N 4919781)
  • 1 x INLINE 6 software CD (P/N 2892095)  Include Insite 7.6.2 + keygen
INLINE 6 Quick Start Guide Introduction   The INLINE 6 is a highly reliable datalink adapter that can be used on a wide range of applications to communicate with vehicle systems via SAE J1708/J1587 and SAE J1939 protocols. Please note that the INLINE 6 is designed to be used with RP1210 compliant software.  Minimum System Requirements  Microprocessor – Intel Pentium 500 MHz  Memory – 2 GB CD Drive  Operating System – Windows 7, Vista, & XP SP3      To Install the INLINE 6 Software Driver • Insert the INLINE 6 driver CD into your computer’s CD-ROM drive.  • Run INLINE6_Driver_Setup.exe  • If a Windows Explorer folder opens, select INLINE6_Driver_Setup.exe  Note that on some systems the autorun settings may be set to have the installation to just begin executing upon CD insertion.    IF YOU SEE: WINDOWS XP - A message appear stating “The software you are installing has not passed Windows Logo…” Click “Continue Anyway”. Click “Finish” when  installation is complete.    

 

To Install the INLINE 6 USB Hardware: To install the INLINE 6 USB hardware, power up the INLINE 6 by plugging in the USB  cable provided with the kit to the INLINE 6 and the PC. 
  • WINDOWS XP - The Found New Hardware wizard should be displayed.On the first screen, select “Install the software automatically (Recommended)”. Click “Next” to continue. A message may appear “This software has not passed Windows Logo Testing……” Select “Continue Anyway”. Click “Finish” when installation is complete. 
  • WINDOWS VISTA/WINDOWS 7 - No action is required. The system tray  should display a balloon stating “Installing Cummins Inline 6”. 
  • NOTE : If there is a previously installed INLINE 6 driver, you may need to remove the older driver before proceeding. 
  • After you have connected your INLINE 6 to your computer and the computer recognizes it as a valid device – you may need to update the firmware in the adapter. Please see the section below on using the INLINE 6 Reflash Tool
 
  • Using Your INLINE 6
  • To use the INLINE 6, you must select it from within the application you areusing. Each application has a unique method for selecting datalink adapters.Please refer to the application’s documentation for instructions on selectingRP1210 compliant adapters.
  •  
  • To Uninstall the INLINE 6 Software Driver 
  • WINDOWS XP- To remove the Cummins INLINE 6 driver, click the “Start”button on the Windows task bar, and then navigate to “Control Panel”. Navigate to “Add or Remove Programs” Click on the entry “Cummins Inline6”. Click the “Remove” button. This will start the uninstall process. Wait until the uninstall process has completed before proceeding. WINDOWS VISTA/WINDOWS 7 – To remove the Cummins INLINE 6 driver, 
  • click the “Start” button on the Windows task bar, and then navigate to “Control 
  • Panel”. Navigate to “Programs/Features” Click the entry “Cummins Inline6’, 
  • Click “Uninstall” at the top of the Programs/Features window. This will start the 
  • uninstall process. Wait until the uninstall process has completed before proceeding. 
  •  

Please Note:

Import duties, taxes and customs clearance fees are not included in the item price or shipping charges. These charges are  the buyer’s responsibility.

Shipping Policy
  • Your order will be shipped within 24-48 hours after payment received and order information confirmed.
  • Expedited Shipping(FedEx/DHL/TNT/UPS/4PX): TO UK 3-7 Workdays, to other countries 3-10 Workdays.
  • Economy Shipping(Post/Airmail): TO United Kingdom, Australia 20-35 Workdays, TO Other countries 20-50 Workdays.
  • Full name, correct telephone number and detailed Physical Address(home or office address) address are necessary.
Payment Method
  • We accept PayPal, VISA, MasterCard, Debit Card through PayPal. 
  • Import duties, taxes and customs clearance fees are not included in the item price or shipping charges. These charges are the buyer’s responsibility.
Returns Policy
  • We offer return or exchange service in the warranty.
  • Refund will be given after receiving the return parts(Buyer pays return shipping).
  • We maintain high standards of excellence POSITIVE FEEDBACK and strive for 100% customer satisfaction!
About US

Maintenance service: repairing for monitor, ECU computer and hydraulic pump; monitor hours resetting, etc.


On 11-Mar-22 at 07:23:07 GMT, seller added the following information:

  • Condition: New
  • Brand: SINOCMP
  • Manufacturer Part Number: 3165033
  • Country/Region of Manufacture: China
  • MPN: 3165033
  • Warranty: 1 Year
  • Origin: CN(Origin)

PicClick Insights - 3165033 Inline 6 Data Link Adapter Diagnostic Tool For Cummins Komatsu TMC's Kit PicClick Exclusive

  •  Popularity - 38 watchers, 0.0 new watchers per day, 1,220 days for sale on eBay. Super high amount watching. 51 sold, 3 available.
  •  Best Price -
  •  Seller - 779+ items sold. 1.5% negative feedback. Great seller with very good positive feedback and over 50 ratings.

People Also Loved PicClick Exclusive