Experience superior monitoring with the Nellcor Compatible SpO2 Sensor, utilising the Nellcor Oximax technology and featuring a proximal connector type of male 9-pin D-Sub purple connector, dual keyed for secure and hassle-free monitoring. This sensor is designed for adult use, providing accurate readings and reliable performance for healthcare professionals seeking precise and efficient monitoring. Invest in the best with the Nellcor Compatible SpO2 Sensor.
Compatibility :
Manufacturer |
Model |
Baxter |
Explorer, Monarch |
Biosys |
BPM-200, SENTRY |
CAS Med |
511 |
Covidien > Nellcor |
Sensors that have Nellcor OxiMax Technology and 9 pins, N-10, N-180, N-190, N-20, N-30, N-560, N-600x, N-65, N-85, NPB-190, NPB-195, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-4000, NPB-75, N-600, NPB-40, PM10N |
Criticare |
506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3 |
DRE |
ASM 5000, Waveline |
Digicare |
LW600 |
Draeger |
Narkomed 6400 |
Fukuda Denshi |
Dynascope DS-7100, LX-7230N |
GE > Critikon > Dinamap |
Compact DINAMAP MPS, Carescape B650, Carescape V100, E-NSAT, Pro 1000, Pro 1000 V3, Pro 200, Pro 300, Pro Series V2, ProCare 200, ProCare 400, ProCare Ausculatory 400 |
GE > Marquette |
Dash 2500, Dash 3000, Dash 4000, Dash 5000 with Nellcor Oximax, i/9500, Procare B40, Solar 8000, Solar 8000M, Tram 451 |
Goldway |
Vet 420A |
Medtronic > Physio Control |
Lifepak 12, Lifepak 15 |
Midmark > Cardell |
9403, 9405, 9500HD |
Mindray > Datascope |
Expert, Passport, Passport XG, Accutorr Plus, DPM5, DPM6, DPM7, Duo, Passport 12, Passport 2, Passport 8, Passport V, Spectrum, Spectrum OR, Trio |
Omron > Colin |
BP-S510, T105NXM |
Philips |
Heartstream XL, IntelliVue, IntelliVue FAST-SpO2, IntelliVue MP70, M1020B, M2601A, M3000A, M3000A/M3001A MMS, M3001A, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, SureSigns VS2, SureSigns VS3, IntelliVue MX450 |
Smiths Medical > BCI |
3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Advisor, Autocorr, Mini Torr, Mini Torr Plus |
Welch Allyn |
53NTP, All, Atlas (Nellcor SpO2), Atlas 6200 Series, Encore 202EL, Propaq 244, Propaq CS, Propaq LT, 1500, 42NT0-E1 LXi, Spot Vital Signs 42NTB-E1, 53NT0 |
Main technical parameters:
Main technical parameters | |
Emitting light waven length |
660±5nm |
Absorbed light wavelength |
905±5nm or 940±5nm |
SpO2 testing range |
70%-100% |
SpO2 testing precision |
±1% in 90%~100% |
±2% in 80%~89% | |
±3% in 70%~79% | |
Testing range of pulse velocity |
30bpm~245bpm |
Testing precision of pulse velocity |
3 0bpm~59bpm,±1bpm |
60bpm~149bpm,±2bpm | |
150bpm~245bpm,±3bpm | |
Working environment requirements | |
Environment temperature |
5°C~40°C |
Relative humidity |
≤80% |
Atmospheric pressure |
700hPa~1060hPa |