STC-1000 12V/24V/110-220V 12-72V Digital Temperature Controller Thermostat NTC

£8.99 Buy It Now, FREE Shipping, 30-Day Returns, eBay Money Back Guarantee
Seller: ai_smart ✉️ (65,590) 99.3%, Location: Glenfield, GB, Ships to: GB, Item: 295315861997 STC-1000 12V/24V/110-220V 12-72V Digital Temperature Controller Thermostat NTC.

Store Categories

Store Categories STC-1000 12/24/110-220V 12-72V Digital Temperature Controller Thermostat NTC UK

Product View

Detail

STC-1000--24V
Designed for perfect fit.
High quality 100% brand new.
Features:
Auto Switch the modes between cool and heat.
Control temperature by setting the temperature setting value and the difference value.
Temperature calibration.
Refrigerating control output delay protection.
Alarm when temperature exceeds temperature limit or when sensor error.
Dimensions:
Front Panel Size: 75(L)×34.5(W) mm.
Mounting Size: 71(L)×29(W) mm.
Product Size: 75(L)×34.5(W)×85(D) mm.
Sensor Cable Length: Approx 2m in all.
Specifications:
Temperature measuring range: -50~99℃.
Resolution: 0.1℃.
Accuracy: ±1℃ (-50~70℃).
Sensor error delay: 1 minute.
Power supply: 24V AC/DC.
Power consumption: ≤3W.
Sensor: NTC sensor (1Pcs).
Relay contact capacity: Cool 10A/250VAC; Heat 10A/250VAC.
Ambient temperature: 0~60℃.
Storage temperature: -30~75℃.
Relative humidity: 20%~85% (No condensate).
Note: This model is 24V AC/DC model, pls check it!


STC-1000--12V
Front Panel Size: 75(L)×34.5(W) mm.
Mounting Size: 71(L)×29(W) mm.
Product Size: 75(L)×34.5(W)×85(D) mm.
Sensor Cable Length: Approx 2m in all.
Specifications:
Temperature measuring range: -50~99℃.
Resolution: 0.1℃.
Accuracy: ±1℃ (-50~70℃).
Sensor error delay: 1 minute.
Power supply: 12V AC/DC.
Power consumption: 3W.
Sensor: NTC sensor (1Pcs).
Relay contact capacity: Cool 10A/250VAC; Heat 10A/250VAC.
Ambient temperature: 0~60℃.
Storage temperature: -30~75℃.
Relative humidity: 20%~85% (No condensate).
Note: This model is 12V AC/DC model, pls check it!


STC-1000--110-220V
Color:Black
Applications:Aquarium, Terrarium, Vivarium, Paludarium ,Chicken Incubator
Temperature Measuring Range: -50 - 90 Deg.C
Control temperature range: -50 - 90 Deg.C (adjustable)
Control temperature difference: 0.3 - 10 Deg.C (adjustable)
Resolution: 0.1 Deg.C
Accuracy: ± 1 Deg.C (-50 - 70 Deg.C)
Sensor: NTC sensor
Sensor error delay: 1 minute
Relay contact capacity (Heating): 10A (max) 250 V
Relay contact capacity (Cooling): 10 A (max) 250 V
Compressor delay protection time: 1 ~ 10 minutes (adjustable)
Operating Temperature: 0 - 60 Deg.C
Storage Temperature: -30 - 75 Deg.C
Operating Relative Humidity: 20 ~ 85 % (No condensation)
Alarm Output : Buzzer
Power Supply: 110~ 220V AC ± 10% , 50 / 60 Hz
Power consumption: < 3 W
Cable length: 1 M
Item dimensions: approx. 84*69*34 MMNet weight:138g


1.5M Wire NTC Sensor
Measurement range: -30 to 110 °C
Length of wire: 1.5m
Size of probe: 4 x 30 mm
Output: 2 wires
Type: NTC 10k±1% 3435
STC-1000 DC 12V-72V Description:
Product Name:Temperature Controller
Product Model:STC1000
Supply Voltage:DC12~72V or AC100~220V (Two voltage options)
Temperature Range:-50~+99°C
Temperature Measurement Accuracy:±1°C(In the range of -50~+70°C)
Line length:1m
Size:75mm*85mm*35mm Applicable Scene:Various Sensor Control Boxes、Water Heater、Freezer、Fan
(Not limited to the devices) Temperature Setting
Heating and Cooling Mode Setting
Setting(Starting Temperature):
Press and hold the▲button 3 seconds to Start Temperature flashing,Use▲▼button to set Start Temperature value
Setting(Stop Temperature):
Press and hold the▼button 3 seconds to Stop Temperature flashing,Use▲▼button to set Stop Temperature value Cases 01 Control Water Heater
Heating to 65℃ to stop, the temperature drops back to 50℃ and heating again
Step1:Heating mode,Starting Temperature<Stop Temperature.
Step2:Press and hold the▲button 3 seconds to Start Temperature value flashing. Use▲▼ to set the Starting Temperature to 50℃.
Step3:Press and hold the▼button 3 seconds to Stop Temperature value flashing. Use▲▼ to set the Stop Temperature to 65℃ and the setting is completed.
The button does not operate for 5 seconds and automatically returns to the normal display state. Cases 02 Control Farm Fan
The fan is ventilated to 26℃ to stop, the temperature is raised to 30℃ and the ventilation is started again.
Step1:Cooling mode,Starting Temperature>Stop Temperature.
Step2:Press and hold the▲button 3 seconds to Start Temperature value flashing. Use▲▼ to set the Starting Temperature to 30℃.
Step3:Press and hold the▼button 3 seconds to Stop Temperature value flashing. Use▲▼ to set the Stop Temperature to 26℃ and the setting is completed.
The button does not operate for 5 seconds and automatically returns to the normal display state.   Package included: 1 x STC-1000 Digital DC12-72V All-Purpose Temperature Controller Thermostat w/Probe
STC-1000 PRO AC110/220V Main Instructing
Switch the modes between cool and heat; Control temperature by setting the temperature setting value and the difference value; Temperature calibration. Refrigerating control output delay protection; Alarm when temperature exceeds temperature limit or when sensor error.
Specification and Size
Front panel size: 75(l)×34.5(w)mm
Sensor length: 2M (include the probe)
Product size: 75(l)×34.5(w)×85(h)mm
Mounting size: 71(l)×29(w)mm
Technical parameters
Temperature measuring range:-50℃~99℃
Resolution:0.1℃
Accuracy:±1℃(-50℃~70℃)
Sensor error delay: 1 minute
Power supply: AC110V~220V
Power consumption:<3W
Relay contact capacity: Cool(10A/AC250V); Heat(10A/AC250V) Sensor: NTC 10K (1pce)
Ambient temperature:0℃~60℃
Storage temperature: -30℃~75℃
Relative humidity:20~85% (No condensate)
Display instruction:
three-digit LED +Minus digit+ Status indicator light (Status indicator light(Cool, Heat)+Set indicator (Set)
Key instruction:
”S”: the key to set; “▲”: Up key;”▼”: Down key; ” ”:the key to turn on and off the power  

Indicator light status instruction

Indicator light

Function

Note

Cool indicator light

On: refrigeration starts; Off: refrigeration stops; flash: compressor delay

Cool, Heat indicator light can not be “on” status simultaneously

Heat indicator light

On: heating starts; Off: heating stops;

Set indicator light

On: parameter setting status

  Key operation instruction
1.The way to check parameter:
Under normal working status, press and release”▲ ” key once instantly, it display temperature setting value; press and release” ▼ ” key once instantly, it displays the difference value. It back to display the normal temperature display status in 2s.
2.The way to set parameter:
Under controller normal working status, press ”S” key for 3s or more to enter parameter modifying mode, and the ”Set” indicator light on, screen display the first menu code”F1”. Press”▲” key to avoid the interference, the sensor down-lead and power wire should be kept a distance or “▼” key to page up and page down menu item to find accordingly code, press“S” key to display the parameter set value of the current menu. press and hold “S” key, press “▲” key or “▼” key again to adjust up and down the parameter setting value of the current menu item. Press and hold both “S” key and “▲” key or “▼”key simultaneously to choose and adjust the parameter value of the current menu value promptly. After finishing the setting, press and release the “  ” key instantly to save the parameter modified value and return to display the normal temperature value. If no key operation within 30 seconds, system won’t save modified parameter, screen back to display normal temperature. Screen display “Er” if error appears during parameter saving, and back to normal working status 3 seconds.
3.Restore system data
When electrified, system will check itself, screen will display “Er” if error exit, please press any key at this time, and it restore default value and enter into normal working mode. It is advised to reset the parameter value under this condition
Operation instruction
Under controller normal working status, press and hold “  ”key for 3s can turn off the controller; under controller “off” status, press and hold “  ” key for 3s can turn on the controller.
Under the controller normal working status, screen display the current temperature value; also the controller can also switch the working mode between heating and cooling.
Controller starts refrigerating with cool indicator light on when the measuring temperature≥temperature set value+ difference value, and the refrigerating relay is connected; the “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
System starts heating when the measuring temperature value ≤the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; when the measuring temperature ≥ temperature set value , the “Heat” indicatorlight is off, and the heat relay disconnects.

Menu instruction

Code

Function

Set range

Default

F1

Temperature set value

-50℃~99℃

10℃

F2

Difference set value

1-10℃

3℃

F3

Compressor delay time

1-10 min

3 min

F4

Temperature calibration value

-10℃~10℃

0℃

  Error description
Alarm when sensor error: controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer, and the nixie tube display ”EE”, press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
Alarm when he measuring temperature exceeds temperature measuring range: controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube display ”HH”, press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
Safety regulations
★Danger
1、Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong connections or overloading the relay.
2、Dangers:prohibit connecting the wire terminals without electricity cut-off.
★Waring
1、Prohibit using the machine under the environment of over damp, high temp, strong electromagnetism interference or strong corrosion.
★Notice
1、The power supply should conform to the voltage value indicated in the instruction.
2、To avoid the interference, the sensor down-lead and power wire should be kept a distance. Shipping Policy

We only accept your Ebay Address ,Please Make sure it's 100% right.

We maintain high standards of excellence and strive for 100% customer satisfaction!

Feedback is very important to us. We request that you contact us immediately BEFORE you give us neutralor or negative feedback, so that we can satisfactorily address your concerns.

          Payment Method Returns Policy

Copyright © 2017 DataCaciques

Product View

Detail

STC-1000--24V
Designed for perfect fit.
High quality 100% brand new.
Features:
Auto Switch the modes between cool and heat.
Control temperature by setting the temperature setting value and the difference value.
Temperature calibration.
Refrigerating control output delay protection.
Alarm when temperature exceeds temperature limit or when sensor error.
Dimensions:
Front Panel Size: 75(L)×34.5(W) mm.
Mounting Size: 71(L)×29(W) mm.
Product Size: 75(L)×34.5(W)×85(D) mm.
Sensor Cable Length: Approx 2m in all.
Specifications:
Temperature measuring range: -50~99℃.
Resolution: 0.1℃.
Accuracy: ±1℃ (-50~70℃).
Sensor error delay: 1 minute.
Power supply: 24V AC/DC.
Power consumption: ≤3W.
Sensor: NTC sensor (1Pcs).
Relay contact capacity: Cool 10A/250VAC; Heat 10A/250VAC.
Ambient temperature: 0~60℃.
Storage temperature: -30~75℃.
Relative humidity: 20%~85% (No condensate).
Note: This model is 24V AC/DC model, pls check it!


STC-1000--12V
Front Panel Size: 75(L)×34.5(W) mm.
Mounting Size: 71(L)×29(W) mm.
Product Size: 75(L)×34.5(W)×85(D) mm.
Sensor Cable Length: Approx 2m in all.
Specifications:
Temperature measuring range: -50~99℃.
Resolution: 0.1℃.
Accuracy: ±1℃ (-50~70℃).
Sensor error delay: 1 minute.
Power supply: 12V AC/DC.
Power consumption: 3W.
Sensor: NTC sensor (1Pcs).
Relay contact capacity: Cool 10A/250VAC; Heat 10A/250VAC.
Ambient temperature: 0~60℃.
Storage temperature: -30~75℃.
Relative humidity: 20%~85% (No condensate).
Note: This model is 12V AC/DC model, pls check it!


STC-1000--110-220V
Color:Black
Applications:Aquarium, Terrarium, Vivarium, Paludarium ,Chicken Incubator
Temperature Measuring Range: -50 - 90 Deg.C
Control temperature range: -50 - 90 Deg.C (adjustable)
Control temperature difference: 0.3 - 10 Deg.C (adjustable)
Resolution: 0.1 Deg.C
Accuracy: ± 1 Deg.C (-50 - 70 Deg.C)
Sensor: NTC sensor
Sensor error delay: 1 minute
Relay contact capacity (Heating): 10A (max) 250 V
Relay contact capacity (Cooling): 10 A (max) 250 V
Compressor delay protection time: 1 ~ 10 minutes (adjustable)
Operating Temperature: 0 - 60 Deg.C
Storage Temperature: -30 - 75 Deg.C
Operating Relative Humidity: 20 ~ 85 % (No condensation)
Alarm Output : Buzzer
Power Supply: 110~ 220V AC ± 10% , 50 / 60 Hz
Power consumption: < 3 W
Cable length: 1 M
Item dimensions: approx. 84*69*34 MMNet weight:138g


1.5M Wire NTC Sensor
Measurement range: -30 to 110 °C
Length of wire: 1.5m
Size of probe: 4 x 30 mm
Output: 2 wires
Type: NTC 10k±1% 3435
STC-1000 DC 12V-72V Description:
Product Name:Temperature Controller
Product Model:STC1000
Supply Voltage:DC12~72V or AC100~220V (Two voltage options)
Temperature Range:-50~+99°C
Temperature Measurement Accuracy:±1°C(In the range of -50~+70°C)
Line length:1m
Size:75mm*85mm*35mm Applicable Scene:Various Sensor Control Boxes、Water Heater、Freezer、Fan
(Not limited to the devices) Temperature Setting
Heating and Cooling Mode Setting
Setting(Starting Temperature):
Press and hold the▲button 3 seconds to Start Temperature flashing,Use▲▼button to set Start Temperature value
Setting(Stop Temperature):
Press and hold the▼button 3 seconds to Stop Temperature flashing,Use▲▼button to set Stop Temperature value Cases 01 Control Water Heater
Heating to 65℃ to stop, the temperature drops back to 50℃ and heating again
Step1:Heating mode,Starting Temperature<Stop Temperature.
Step2:Press and hold the▲button 3 seconds to Start Temperature value flashing. Use▲▼ to set the Starting Temperature to 50℃.
Step3:Press and hold the▼button 3 seconds to Stop Temperature value flashing. Use▲▼ to set the Stop Temperature to 65℃ and the setting is completed.
The button does not operate for 5 seconds and automatically returns to the normal display state. Cases 02 Control Farm Fan
The fan is ventilated to 26℃ to stop, the temperature is raised to 30℃ and the ventilation is started again.
Step1:Cooling mode,Starting Temperature>Stop Temperature.
Step2:Press and hold the▲button 3 seconds to Start Temperature value flashing. Use▲▼ to set the Starting Temperature to 30℃.
Step3:Press and hold the▼button 3 seconds to Stop Temperature value flashing. Use▲▼ to set the Stop Temperature to 26℃ and the setting is completed.
The button does not operate for 5 seconds and automatically returns to the normal display state.   Package included: 1 x STC-1000 Digital DC12-72V All-Purpose Temperature Controller Thermostat w/Probe
STC-1000 PRO AC110/220V Main Instructing
Switch the modes between cool and heat; Control temperature by setting the temperature setting value and the difference value; Temperature calibration. Refrigerating control output delay protection; Alarm when temperature exceeds temperature limit or when sensor error.
Specification and Size
Front panel size: 75(l)×34.5(w)mm
Sensor length: 2M (include the probe)
Product size: 75(l)×34.5(w)×85(h)mm
Mounting size: 71(l)×29(w)mm
Technical parameters
Temperature measuring range:-50℃~99℃
Resolution:0.1℃
Accuracy:±1℃(-50℃~70℃)
Sensor error delay: 1 minute
Power supply: AC110V~220V
Power consumption:<3W
Relay contact capacity: Cool(10A/AC250V); Heat(10A/AC250V) Sensor: NTC 10K (1pce)
Ambient temperature:0℃~60℃
Storage temperature: -30℃~75℃
Relative humidity:20~85% (No condensate)
Display instruction:
three-digit LED +Minus digit+ Status indicator light (Status indicator light(Cool, Heat)+Set indicator (Set)
Key instruction:
”S”: the key to set; “▲”: Up key;”▼”: Down key; ” ”:the key to turn on and off the power  

Indicator light status instruction

Indicator light

Function

Note

Cool indicator light

On: refrigeration starts; Off: refrigeration stops; flash: compressor delay

Cool, Heat indicator light can not be “on” status simultaneously

Heat indicator light

On: heating starts; Off: heating stops;

Set indicator light

On: parameter setting status

  Key operation instruction
1.The way to check parameter:
Under normal working status, press and release”▲ ” key once instantly, it display temperature setting value; press and release” ▼ ” key once instantly, it displays the difference value. It back to display the normal temperature display status in 2s.
2.The way to set parameter:
Under controller normal working status, press ”S” key for 3s or more to enter parameter modifying mode, and the ”Set” indicator light on, screen display the first menu code”F1”. Press”▲” key to avoid the interference, the sensor down-lead and power wire should be kept a distance or “▼” key to page up and page down menu item to find accordingly code, press“S” key to display the parameter set value of the current menu. press and hold “S” key, press “▲” key or “▼” key again to adjust up and down the parameter setting value of the current menu item. Press and hold both “S” key and “▲” key or “▼”key simultaneously to choose and adjust the parameter value of the current menu value promptly. After finishing the setting, press and release the “  ” key instantly to save the parameter modified value and return to display the normal temperature value. If no key operation within 30 seconds, system won’t save modified parameter, screen back to display normal temperature. Screen display “Er” if error appears during parameter saving, and back to normal working status 3 seconds.
3.Restore system data
When electrified, system will check itself, screen will display “Er” if error exit, please press any key at this time, and it restore default value and enter into normal working mode. It is advised to reset the parameter value under this condition
Operation instruction
Under controller normal working status, press and hold “  ”key for 3s can turn off the controller; under controller “off” status, press and hold “  ” key for 3s can turn on the controller.
Under the controller normal working status, screen display the current temperature value; also the controller can also switch the working mode between heating and cooling.
Controller starts refrigerating with cool indicator light on when the measuring temperature≥temperature set value+ difference value, and the refrigerating relay is connected; the “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
System starts heating when the measuring temperature value ≤the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; when the measuring temperature ≥ temperature set value , the “Heat” indicatorlight is off, and the heat relay disconnects.

Menu instruction

Code

Function

Set range

Default

F1

Temperature set value

-50℃~99℃

10℃

F2

Difference set value

1-10℃

3℃

F3

Compressor delay time

1-10 min

3 min

F4

Temperature calibration value

-10℃~10℃

0℃

  Error description
Alarm when sensor error: controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer, and the nixie tube display ”EE”, press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
Alarm when he measuring temperature exceeds temperature measuring range: controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube display ”HH”, press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
Safety regulations
★Danger
1、Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong connections or overloading the relay.
2、Dangers:prohibit connecting the wire terminals without electricity cut-off.
★Waring
1、Prohibit using the machine under the environment of over damp, high temp, strong electromagnetism interference or strong corrosion.
★Notice
1、The power supply should conform to the voltage value indicated in the instruction.
2、To avoid the interference, the sensor down-lead and power wire should be kept a distance. Shipping Policy

1.We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.

2.Orders will be processed instantly and dispatched within 1-2 business days except hoilday, so we do NOT accept any email/message note after you place orders.

3.Usually, the package will be delivered in about 30 days, some remote areas may wait longer.

Payment Method

1.We accept PayPal payment, and must be received within 5 days from the date of purchase.

2. It is easy and safe for you to pay by credit cards, debit cards, bank transfers and PayPal account balances.

3.Buyers are responsible for import duties,custom fees and taxes, if any, please check your country.

Returns Policy

1.We believe our items are so outstanding. We are convinced you will be happy with your Purchase.

2. If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund or resend the item to you after the returned item arrived at our warehouse.

3. Please include your eBay ID and item number with any email requests.

Feedback

1.We greatly appreciate your POSITIVE feedback. Please do NOT leave negative feedback or open a case without asking for help.

2.Please DON'T leave negative / neutral feedback or open case if you haven't received item in 30 days, International shipping is uncontrollable, sometimes the package may be delayed, If you have't receive item in time, Please remember to contact us to resolve.

Contact Us

1. If you have any questions, please feel free to email our service specialists.

2.Just contact us using the " Ask the seller a question" link on eBay.

3.Our aim is to provide Top Level Customer Service, normally so we will try our best to solve any problem.

  • Condition: New
  • option: 12V STC-1000
  • Brand: Unbranded
  • Herstellungsland und -region: China
  • Marke: Markenlos
  • Produktart: NTC-Temperatursensor
  • Marque: - Sans marque/Générique -

PicClick Insights - STC-1000 12V/24V/110-220V 12-72V Digital Temperature Controller Thermostat NTC PicClick Exclusive

  •  Popularity - 55 watchers, 0.1 new watchers per day, 530 days for sale on eBay. Super high amount watching. 64 sold, 47 available.
  •  Best Price -
  •  Seller - 65,590+ items sold. 0.7% negative feedback. Great seller with very good positive feedback and over 50 ratings.

People Also Loved PicClick Exclusive