Landis+Gyr E470 Single Phase Smart Meter 100A Direct Connected
The Landis+Gyr E470 Single Phase Smart Meter 100A Direct Connected is ideal for use in residential buildings and has several features which help overcome problems associated with prepayment systems. In addition to ably performing all the functions one would expect of a single phase smart meter, the Landis+Gyr E470 uses SMS messaging rather than GSM which therefore allows token-less prepayment as well as remote meter reading and programming. Token-less payment avoids problems such as token loss, out of hours calls, and other associated issues, thereby making life easier for providers, consumers, landlords, homeowners and tenants.
The Landis+Gyr is suitable for standard domestic circuits and is MID approved so the user can have confidence in the device. The clear, backlit screen means that it is easy to operate and message encryption provides security and peace of mind. Overall, it is a great way of streamlining prepayment services and monitoring electricity use in a residential setting. The user can go to www.meteronline.co.uk to monitor the meter remotely.
Key Features
· Suitable for residential properties
· SMS messaging allows token-less prepayment
· MID-approved
· Meter Type: 5236J-Y (electronic token-less prepayment meter)
· Compliant with BS EN 61036 1996, BS EN 62056-21, BS EN 61000-4-5
· Single Phase Network
· Measuring Range: 0.5 – 10 (100)A
· Class A or B accuracy
· Digital backlit display
· Reference Voltage / Frequency: 220 - 240v / 50Hz
· Operating Voltage Range: -20% to +15%
· Current Range: 0.5-10 (100) A; 0.75-15 (100)A; 1-20(100)A
· Contactor: 100 Amp
· Auxilary Terminal 2A off peak load control relay
· Communications Optical Port [IEC62056-21] remotely via encrypted SMS/GSM
· Quality: ISO9001:2000
· Reference Standards: EN50470-1 EN50470-3
General
Voltage
· Nominal Voltage Un 220, 230, 240V
· Voltage Range 80-115%Un
· Voltage Withstand 415V Continuous
Frequency
· Nominal Frequency 50Hz
· Frequency Variation +/- 2%
MID-specific data
Current
Base Current
· Direct Connection Iref: 10A,15A or 20A
· Imax 100A
Starting Current
· MID Class B: 0.04 Itr
· MID Class A: 0.05 Itr
Measurement Accuracy
· Max Measuring Range: 40mA up to 100A
Measuring Accuracy
· Active Energy MID: Class A or B
General
Operating Behaviour
Voltage Interruptions (Power Down)
· Blocking of inputs and outputs: Immediate
· Standby Operation for: 0.15s
· Data Storage after: 0.15s
· Switch Off after: approx 0.15s
Voltage Restoration (Power Up)
· Function Standby (depending on duration of failue): <5s
· Detection of energy direction and phase voltage: <5s
Power Supply Quality
· The meter complies with EN63052-11 Section 7.1. 'Voltage range' and 7.1.2 'Voltage dips and short interruptions'
Power Consumption
· Voltage Circuit: <5W / <25VA
· Current Circuit: <2.5VA
Environmental Influences
· Temperature: Test IEC
Temperature Range
· Operation: -25°C to +55°C
· Power Measurement Range: -25°C to +55°C
· Storage: -25°C to +55°C
· This complies with EN 62052-11:2003 section 6.1
Temperature Coefficient
· Range From -25°C to +55°C
· Typical mean value ±0.015% per K
· cos=1 (from Imin to Imax) ±0.05% per K
· cos=0.5 (from Itr to Imax) ±0.07% per K
· Impermeability to IEC 60529: IP51
· Shock Test: BS EN60068-2-27
Electromagnetic Compatibility
· Electrostatic Discharges: to IEC 610000-4-2
· Contact Discharges: 8kV
· Air Discharges: 15kV
· Electromagnetic RF Fields: to IEC 610000-4-3
80 MHz to 2 GHz: at least 10V/m
· Radio Interference suppression: to IEC 55022 Class B
· Fast Transient Burst Test to IEC 610000-4-4
With basic current Ib:
· For current and voltage circuits: 4kV
· For auxiliary circuits >40V: 4kV
· With open current circuit for voltage and current circuits: 4kV
Fast Transient Surge Test to IEC 610000-4-5
· Impulse Voltage: 4kV
· Impedance of source: 2Ω
· Rise/Decay time of impulse voltage: 1.2µs/50µs
· Rise/Decay time of impulse voltage: 8µs/50µs
Insulation Strength
· Insulation Strength: 4.4kV at 50Hz for 80 seconds
· Impulse Voltage Strength: to IEC62053-11
· Impulse Voltage: 6kV
· Impedance of source: 500Ω
· Rise/Decay time of impulse voltage 1.2µs/50µs
· Protection Class II to IEC50470-1 2: 3/4
Display
Characteristics
· Type: 7 character, 7 segment, LCD
· Digit size: 8 x 3.5mm
· Number of Digits: 6 significant numbers 2dp
Communication interfaces
Optical Interface
· Type Serial, bi-directional interface
· Protocol: IEC62056-21
Case Material
Base, Top Cover and Terminal Cover
· Flame retardant and UV stabilised polycarbonate
Weight and Dimensions
Weight
· Standard: 750g
Dimensions
· Width: 175mm
· Height: 126mm
· Depth: 55mm
Terminal Details
· Arrangement: BS5685
· Size: 8.3mm diameter