Touch Screen Digital 6-Channel 12 lead ECG EKG machine electrocardiogram PC SW

Unsold See similar items £533.00 Buy It Now or Best Offer, FREE Shipping, 60-Day Returns, eBay Money Back Guarantee
Seller: joywang011 ✉️ (469) 98.2%, Location: 秦皇岛, CN, Ships to: WORLDWIDE, Item: 224936822320 Touch Screen Digital 6-Channel 12 lead ECG EKG machine electrocardiogram PC SW. 5 Pictures

Touch Screen Digital 6-Channel 12 lead ECG EKG machine electrocardiogram PC SW

Description          

Introduction E6 is a kind of electrocardiograph, which is able to sample 12 leads ECG signals simultaneously and print out the ECG waveform with thermal printing system. Its functions are as follows: recording and displaying ECG waveform in auto/manual mode; measuring ECG waveform parameters automatically, and automatic analysis and diagnosis; pacing ECG detection; prompt for electrode-off and out of paper; optional interface languages(Chinese/English, etc.); built-in lithium battery, powered either by AC or DC; arbitrarily select the rhythm lead to conveniently observe abnormal heart rhythm; case database management, etc. Note: The device sold to the countries and regions that have FDA certification requirement does not support automatic analysis and diagnosis function. Function 1) Adopt 7'' high-resolution color LCD, operate by touch screen and function buttons, convenient to use. 2) Sync collection for 12-lead ECG, support routine 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via AC filter, DFT filter, EMG filter and Low-pass Filter of ECG signal. 3) Display 3/6/12 - lead ECG waveform, print mode, sensitivity, paper speed, filter status, etc. on one screen, convenient for contrastively diagnosing. 4) Power supply: AC/DC (which can adapt AC 50/60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit. 5) Support for auto 1*12, auto 2*6, auto 2*6+1, auto 3*4, auto 3*4+1, auto 4*3, auto 4*3+1, auto 6*2, auto 6*2+1, rhythm 7, rhythm 6, rhythm 5, rhythm 4, rhythm 3, rhythm 2 and manual. The printed content contains time, calibration signal, filter status and patient’s information. Information including printed waveform length, output measurement parameters, diagnostic conclusion, superposition QRS wave, histogram, trend chart, interval list, can be set, and with time print function, which meets different requirements. 6) With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measurement results for HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5), S(V1) and R(V5)+S(V1), etc. and auto-diagnosis conclusion, which reduces the doctor’s burden. 7) Rhythm lead can be selected freely, convenient to observe abnormal heart rhythm. 8) The subject’s clinical information (such as, ID, Name, Age, Sex, Height, Weight, etc.) can be entered. 9) 1000 cases (3 s case is frequently used) can be stored by the built-in memory, convenient for case review and statistic. 10) In optimal DC state, up to 10-hour standby time, continuous print for more than 3-hour and print up to 1000 ECG waveform (3 s case is frequently used). 11) Multi-language (Chinese, English, Turkish, Portuguese, German, Russian and Kazakh, etc.) interface and report. 12) External printer and USB storage device can be connected. Performance Input way: Floating and defibrillation protection Lead: Standard 12 leads Patient leakage current: <10µA Input impedance: ≥100 MΩ(1Hz) Frequency response: 0.01Hz~300 Hz(-3dB) Time constant: ≥3.2s CMRR: >123 dB Filter: AC Filter(AC50/60 Hz), EMG Filter (25 Hz/35 Hz (-3 dB)), DFT Filter, Low-pass Filter Recording way: Thermal printing system Specification of recording paper: 110 mm(W)×20 m(L) high-speed thermal paper Time base selection(paper speed): 5 mm/s, 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s, 100 mm/s, error: ±5% within 0.2s~2.0s Gain control(sensitivity): 2.5、5、10、20、40、10/5、20/10 mm/mV, accuracy is ±5%; Standard sensitivity: 10 mm/mV±0.2 mm/mV Auto record: record setup according to auto record format and mode, automatically change leads, automatically measure and analyze. Rhythm record: record setup according to rhythm record format and mode, automatically measure and analyze. Manual record: record according to manual record format. Measurement parameters: HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5), S(V1) and R(V5)+S(V1) amplitude Product safety type: Class I type CF defibrillation-proof applied part Polarization resistance voltage: ±950 mV Noise level: ≤12 µVp-p ECG signal input sampling frequency: 32 kHz Waveform data processing sampling frequency: 1 kHz Sampling precision: 24-bit The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected Pacing detection channel: all leads Accuracy of input signal: ±5% Amplitude quantization: ≤5µV/LSB Interchannel time deviation: <100 µs Power supply:  AC: 100V~240V(50/60Hz) DC: 7.4V/5000mAh rechargeable lithium battery Degree of protection against ingress of liquid: IPX0 Working mode: continuous working Accessories Standard configuration: A lead cable A limb electrode A chest electrode A thermal recording paper A power cord An earth wire A user manual Physical characteristic Working environment Temperature: 5℃~40℃ Relative humidity: 25%~95%(non-condensing) Atmospheric pressure: 700 hPa~1060 hPa Transport and storage environment Temperature: -20 ℃~+55 ℃ Relative humidity: ≤95% Atmospheric pressure: 500 hPa~1060 hPa Dimension: 315mm(L)×200mm(W)×92mm(H) Weight: 1.7Kg

Shipping By Airmail:  Generally, about 2-3 weeks By Express: Generally, about 5-10 working days to UK, USA, AU and so on.               We can also ship the item through express service like DHL, UPS, if you are ready to pay the  extra charge.

Terms of Sale Buy Safe Product! The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923,and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved Taxes, Customs & Duties              There are not extra taxes, VAT or other unmentioned payment. You pay us with goods subtotal + shipping cost (not include duties). But you need to pay for the import duties in case that occurred for certain goods. Return - After service We offer 60 days return policy. 100% satisfaction is our goal! 1.All items are brand new ,with 1 years warranty.               2.We will refund the money to you when we get the return items or replace item for you.

About Us Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.At present there are more than 1200 employees in our company. We are looking forward to establishing a successful business relationship with you. Only english user guide,if you need any other language,please contact me.
  • Condition: New
  • Number of Channels: 6
  • ECG & EKG Machine Type: Electrocardiograph
  • Number of Leads: 12 lead
  • Mounting: Trolley Mounted
  • Features: Printer
  • Operation: Digital
  • MPN: 69450401
  • Brand: CON-TEC
  • Intended Use/Discipline: Emergency Medicine

PicClick Insights - Touch Screen Digital 6-Channel 12 lead ECG EKG machine electrocardiogram PC SW PicClick Exclusive

  •  Popularity - 0 watchers, 0.0 new watchers per day, 672 days for sale on eBay. 0 sold, 10 available.
  •  Best Price -
  •  Seller - 469+ items sold. 1.8% negative feedback. Great seller with very good positive feedback and over 50 ratings.

People Also Loved PicClick Exclusive